CytoFLEX mosaic 88 Spectral Detection Module U-V-B-Y-R-I (6 laser, CytoFLEX LX UV)

CytoFLEX mosaic 88 Spectral Detection Module U-V-B-Y-R-I (6 laser, CytoFLEX LX UV)

Product no. D19581

Configuration Before UpgradeSensitivity: FITC: <30 molecules of equivalent soluble fluorochrome (MESF-FITC), PE: <10 molecules of equivalent soluble fluorochrome (MESF-PE), APC: <25 molecules of equivalent soluble fluorochrome (MESF-APC), Fluorescence sensitivity is measured based on peak channel testing results, Scatter Resolution: Blue (488 nm) Side Scatter Resolution: <300 nm, Violet (405 nm) Side Scatter Resolution (VSSC): 80 nm relative to polystyrene particles, Scatter performance is optimized for resolving human lymphocytes, monocytes, and granulocytes as well as nanoparticles, Detectors: Avalanche Photodiode Detectors, Number of Detectors: 88
Depth34.5 cm
Height53.5 cm
Open Text Additional DetailsSensitivity: FITC: <30 molecules of equivalent soluble fluorochrome (MESF-FITC), PE: <10 molecules of equivalent soluble fluorochrome (MESF-PE), APC: <25 molecules of equivalent soluble fluorochrome (MESF-APC), Fluorescence sensitivity is measured based on peak channel testing results, Scatter Resolution: Blue (488 nm) Side Scatter Resolution: <300 nm, Violet (405 nm) Side Scatter Resolution (VSSC): 80 nm relative to polystyrene particles, Scatter performance is optimized for resolving human lymphocytes, monocytes, and granulocytes as well as nanoparticles, Detectors: Avalanche Photodiode Detectors, Number of Detectors: 88
Power RequirementsVoltage: 100–240 V Power: CytoFLEX mosaic 88 450VA
Regulatory StatusRUO
Signal ProcessingFully digital system with 7-decade data display
SoftwareCytExpert for Spectral
Weight33 kg
Width42.5 cm
CytoFLEX mosaic 88 Spectral Detection Module U-V-B-Y-R-I (6 laser, CytoFLEX LX UV)
© Beckman Coulter, Inc. All rights reserved.

Beckman Coulter, the stylized logo, and the Beckman Coulter product and service marks mentioned herein are trademarks or registered trademarks of Beckman Coulter, Inc. in the United States and other countries. All other trademarks are the property of their respective owners.

NOT ALL PRODUCTS ARE AVAILABLE IN ALL COUNTRIES. PRODUCT AVAILABILITY AND REGULATORY STATUS DEPENDS ON COUNTRY REGISTRATION PER APPLICABLE REGULATIONS The listed regulatory status for products correspond to one of the below: IVD: In Vitro Diagnostic Products. These products are labeled "For In Vitro Diagnostic Use." ASR: Analyte Specific Reagents. These reagents are labeled "Analyte Specific Reagent. Analytical and performance characteristics are not established." CE-IVD, CE: Products intended for in vitro diagnostic use and conforming to the In Vitro Diagnostic Regulation (IVDR) (EU) 2017/746. (Note: Devices may be CE marked to other directives.) RUO: Research Use Only. These products are labeled "For Research Use Only. Not for use in diagnostic procedures." LUO: Laboratory Use Only. These products are labeled "For Laboratory Use Only." No Regulatory Status: Non-Medical Device or non-regulated articles. Not for use in diagnostic or therapeutic procedures.